324Cast-in-placeElectrical
Robey Rod
Protects PVC coated MC, PVC and ENT (smurf tube) fittings during the pour: hook one on each side of the box.

In use.
Function
Pre-pour
Temporary securement device: positions and secures the utility before and during the concrete pour.
No rating
No load rating is published; the cured concrete carries the utility.
The cured concrete carries the utility.
Order
Order the part
Add parts to your list, then request a quote, a submittal package, or both. Pricing follows by reply.
Standard parts
- 324A01Robey RodA01 1 in. loop ID; for PVC coated MCA · No load rating published
- 324A02Robey RodA02 1.5 in. loop ID; for 3/4 and 1 in. PVC and ENT (smurf tube) · No load rating published
Built to order
A03 Custom dimensions
Your part number
324A03
Finish the selections to complete the request.
Installation
- Hook the PVC coated MC, ENT (smurf tube) or PVC conduit on one side of the box.
- Do the same thing on the other side; one Robey Rod protects each fitting.
From the data sheet
Notes
- Protects PVC coated MC, PVC and ENT (smurf tube) fittings during the pour: hook one on each side of the box.
- Fixed 12 in. x 1.5 in. dimensions; can be changed per order.
- Galvanized rod; corrosion resistant.
- Rigid support: stable pipe and conduit positioning during the pour.
- Designed for demanding high-rise construction.
- Electrical: positions PVC conduit, PVC-coated GRC and ENT raceways, boxes and fittings in the pour (NEC 352.30, 344.30, 362.30), secured so they cannot float or shift; spacing per the specifications and the manufacturer.
- Drawings not to scale.